ATX12V
300W mini redundant Power Supply
300+300
watts Output power
1+1
Redundant Configuration
PSII
Mini Redundant Power
Meet
4U Rackmount Application
Dimensions:
150(W) x 86(H) x 175(D) mm
|
Features:
Universal
Power Input
Front
panel LED to Indicate Power Status
Available
for Dual AC Input Type
Remote
DC Sense on +5V and +3.3V
Power
Fault Alarm Signals
Over
Voltage Protection
Over
Current Protection
Over
Power Protection
Short
Circuit Protection
MTBF
>100,000 Hours
|
General
Specifications:
Input
Range: 100
to 240 VAC, +/-10%
Power
Factor: 0.95 minimum
Efficiency:
65% minimum, at full load
Hold
up Time: 20mS minimum, at full load
PSON
(Remote ON/OFF): TTL compatible signal
Power
Good: 100 to 500 ms, TTL compatible signal
Cooling
Fan: 60x60x20 mm
Operating
Temperature: 0 to 50 degree
Operating
Humidity: 20 to 90 %
|
|
Electrical
Specifications:
Regulation,
Ripple & Noise:
Output
|
+5V
|
+3.3V
|
+12V
|
-5V
|
-12V
|
5Vsb
|
|
Load
Regulation
|
±
5%
|
±
5%
|
±
5%
|
±
10%
|
±
10%
|
±
5%
|
|
Cross
Regulation
|
±
5%
|
±
5%
|
±
5%
|
±
10%
|
±
10%
|
±
5%
|
|
Line
Regulation
|
±
1%
|
±
1%
|
±
1%
|
±
1%
|
±
1%
|
±
1%
|
|
Ripple
& Noise
|
50mV
|
50mV
|
120mV
|
100mV
|
120mV
|
50mV
|
Input
and Output Ratings:
|
Input
|
Output
|
|
Frequency
|
Current
|
Watt
|
Load
|
+5V
|
+3.3V
|
+12V
|
-5V
|
-12V
|
5Vsb
|
|
47-63
Hz
|
6A
max
|
300W
|
Max
Load
|
36A
|
16A
|
14A
|
0.5A
|
1.0A
|
2A
|
|
Min
Load
|
3A
|
1A
|
1A
|
0A
|
0A
|
0A
|
Note:
1. The +5 & +3.3 Volt combine total output shall not exceed
150W.
2.
The +5, +3.3 and +12 Volt combine total output shall not exceed
270W.
3:
Noise bandwidth is from DC to 20 MHz.
Toll Free
: 1-888-865-6888
Fax : 510-226-8968 Email :
sales@RackmountMart.com
|